RFID
A basic RFID system consist of three components:
The
antenna emits radio signals to activate the tag and read and
write data to it. Antennas are the conduits between the tag and
the transceiver, which controls the system's data acquisition
and communication. Antennas are available in a variety of shapes
and sizes; they can be built into a door frame to receive tag
data from persons or things passing through the door, or mounted
on an interstate toll booth to monitor traffic passing by on a
freeway. The electromagnetic field produced by an antenna can be
constantly present when multiple tags are expected continually.
If constant interrogation is not required, the field can be
activated by a sensor device.
Often
the antenna is packaged with the transceiver and decoder to
become a reader (a.k.a. interrogator), which can be configured
either as a handheld or a fixed-mount device. The reader emits
radio waves in ranges of anywhere from one inch to 100 feet or
more, depending upon its power output and the radio frequency
used. When an RFID tag passes through the electromagnetic zone,
it detects the reader's activation signal. The reader decodes
the data encoded in the tag's integrated circuit (silicon chip)
and the data is passed to the host computer for processing.
RFID
tags come in a wide variety of shapes and sizes. Animal tracking
tags, inserted beneath the skin, can be as small as a pencil
lead in diameter and one-half inch in length. Tags can be
screw-shaped to identify trees or wooden items, or credit-card
shaped for use in access applications. The anti-theft hard
plastic tags attached to merchandise in stores are RFID tags. In
addition, heavy-duty 5- by 4- by 2-inch rectangular transponders
used to track intermodal containers or heavy machinery, trucks,
and railroad cars for maintenance and tracking applications are
RFID tags.
RFID
tags are categorized as either active or passive. Active RFID
tags are powered by an internal battery and are typically
read/write, i.e., tag data can be rewritten and/or modified. An
active tag's memory size varies according to application
requirements; some systems operate with up to 1MB of memory. In
a typical read/write RFID work-in-process system, a tag might
give a machine a set of instructions, and the machine would then
report its performance to the tag. This encoded data would then
become part of the tagged part's history. The battery-supplied
power of an active tag generally gives it a longer read range.
The trade off is greater size, greater cost, and a limited
operational life (which may yield a maximum of 10 years,
depending upon operating temperatures and battery type).
Passive RFID tags operate without a separate external power
source and obtain operating power generated from the reader.
Passive tags are consequently much lighter than active tags,
less expensive, and offer a virtually unlimited operational
lifetime. The trade off is that they have shorter read ranges
than active tags and require a higher-powered reader. Read-only
tags are typically passive and are programmed with a unique set
of data (usually 32 to 128 bits) that cannot be modified.
Read-only tags most often operate as a license plate into a
database, in the same way as linear barcodes reference a
database containing modifiable product-specific information.
RFID
systems are also distinguished by their frequency ranges.
Low-frequency (30 KHz to 500 KHz) systems have short reading
ranges and lower system costs. They are most commonly used in
security access, asset tracking, and animal identification
applications. High-frequency (850 MHz to 950 MHz and 2.4 GHz to
2.5 GHz) systems, offering long read ranges (greater than 90
feet) and high reading speeds, are used for such applications as
railroad car tracking and automated toll collection. However,
the higher performance of high-frequency RFID systems incurs
higher system costs.
The
significant advantage of all types of RFID systems is the
noncontact, non-line-of-sight nature of the technology. Tags can
be read through a variety of substances such as snow, fog, ice,
paint, crusted grime, and other visually and environmentally
challenging conditions, where barcodes or other optically read
technologies would be useless. RFID tags can also be read in
challenging circumstances at remarkable speeds, in most cases
responding in less than 100 milliseconds. The read/write
capability of an active RFID system is also a significant
advantage in interactive applications such as work-in-process or
maintenance tracking. Though it is a costlier technology
(compared with barcode), RFID has become indispensable for a
wide range of automated data collection and identification
applications that would not be possible otherwise.
Developments in RFID technology continue to yield larger memory
capacities, wider reading ranges, and faster processing. It is
highly unlikely that the technology will ultimately replace
barcode — even with the inevitable reduction in raw materials
coupled with economies of scale, the integrated circuit in an RF
tag will never be as cost-effective as a barcode label. However,
RFID will continue to grow in its established niches where
barcode or other optical technologies are not effective. If some
standards commonality is achieved - whereby RFID equipment from
different manufacturers can be used interchangeably - the market
will very likely grow exponentially. |